C4B-4170N
◼Forced open action device (NC contacts only), to disconnect the contact
when the contact has fusing and other failures
◼Strengthened top seal structure improves the sealing performance
◼Built-in contact holder has fast-action type: 1NC / 1NO; Slow-action:
1NC / 1NO and 2NC
Item |
Code |
Description |
① Conduit / connector size |
1 |
Pg13.5 (1 conduit type) |
4 |
M20 (1 conduit type) |
|
② Built-in switch |
1 |
1NC/1NO (quick-action type) |
5 |
1NC/1NO (slow-action type) |
|
A |
2NC (slow-action type) |
|
③Head and driving rod |
11 |
Roller lever (resin lever, resin ball) |
12 |
Adjustable roller lever, Form-Lock (metal lever, metal ball) |
|
15 |
Roller lever (metal ball) |
|
16 |
Adjustable roller lever, Form-Lock (resin ball) |
|
17 |
Adjustable stick lever, Form-Lock (long lever) |
|
18 |
Adjustable roller lever, Form Lock (metal lever, rubber ball) |
|
70 |
Top ball plunger type |
|
71 |
Ball plunger type |
|
72 |
Ball plunger type |
|
81 |
Coil spring type |
|
87 |
Plastic stick type |
|
86 |
Metal stick type |
Ratings
Rated voltage (V) |
Non-inductive load (A) |
Inductive load (A) |
|||||||
Resistive load |
Lamp load |
Inductive load |
Motor load |
||||||
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
||
AC |
125 |
10 |
3 |
1.5 |
10 |
5 |
2.5 |
||
250 |
10 |
2 |
1 |
10 |
3 |
1.5 |
|||
400 |
10 |
1.5 |
0.8 |
3 |
1.5 |
0.8 |
|||
DC |
8 |
10 |
6 |
3 |
10 |
6 |
|||
14 |
10 |
6 |
3 |
10 |
6 |
||||
30 |
6 |
4 |
3 |
6 |
4 |
||||
125 |
0.8 |
0.2 |
0.2 |
0.8 |
0.2 |
||||
250 |
0.4 |
0.1 |
0.1 |
0.4 |
0.1 |
NOTE: The default size of conduit connector is M20x1.5.
Note1.The above values represent constant current.
2.The so-called inductive load refers to the load with power factor of 0.4 or more (AC) and the time constant below 7ms (DC).
3.The so-called lamp load refers to the load with 10 times of surge current. 4.The so-called motor load is the load with 6 times of surge current.
Operating Characteristic
Model Action characteristics |
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
C4B-
|
||
Action force |
OF |
Max. |
9.41N |
9.41N |
9.41N |
2.12N |
9.41N |
18.63N |
18.63N |
1.47N |
1.47N |
1.47N |
Restore force |
RF |
Min. |
1.47N |
1.47N |
1.47N |
0.29N |
1.47N |
1.96N |
1.96N |
|||
Pretravel |
PT |
21°±3° |
21°±3° |
21°±3° |
21°±3° |
21°±3° |
2mm |
2mm |
15 |
15 |
15 |
|
PT |
(2nd) *3 *5 |
(45° ) |
(45° ) |
(45° ) |
(45° ) |
(45° ) |
(3mm) |
(3mm) |
||||
Overtravel |
OT |
Min. |
50° |
50° |
50° |
50° |
50° |
5mm |
5mm |
|||
Poor response travel |
MD |
Max. *4 |
12° |
12° |
12° |
12° |
12° |
1mm |
1mm |
|||
Forced disconnected pretravel |
DOT |
Min. *3*6 *4*6 |
35° |
35° |
35° |
35° |
35° |
3.2mm |
3.2mm |
|||
55° |
55° |
55° |
55° |
55° |
||||||||
Forced disconnected force |
DOF |
Min. *6 |
19.61N |
19.61N |
19.61N |
19.61N |
19.61N |
49.03N |
49.03N |
|||
Total travel |
TT |
*5 |
(75°) |
(75°) |
(75°) |
(75° ) |
(75° ) |
(7mm) |
(7mm) |
|||
Free position |
FP |
Max. |
38mm |
51mm |
||||||||
Action position |
OP |
35±1mm |
48±1mm |
Note The simultaneity of ON / OFF operation of 2NC contacts have difference, please make sure before using it.
*1. The property value when length of lever is 31.5mm.
*2. The property value when length of lever is 140mm.
*3. Only for slow-action type.
*4. Only for quick-action type.
*5. Reference values.
*6. Please make sure in order to ensure the safe use.
Protection level |
IP66 |
|
Life |
Electrical |
More than 500,000 times |
Operating speed |
1mm~0.5m/s |
|
Operating frequency |
Mechanical |
120 次 /min 120 times/min |
Electrical |
30 次 /min 30 times/min |
|
Rated frequency |
50/60Hz |
|
Insulation resistance |
100MΩ or more (DC500V Megameter) between homopolars, and between terminals and uncharged metal parts |
|
Contact resistance |
5mΩ or less (initial value) |
|
Withstand voltage (EN60947-5-1) |
Between homopolar terminals: 2.5kV(quick-action type)/4kV(slow-action type) |
|
Between heteropolar terminals: 2.5kV(slow-action type) |
||
Between charged metal parts: 4kV |
||
Between terminals and uncharged metal parts: 6kV |
||
Rated insulation voltage (Ui) |
600V(EN60947-5-1) |
|
Reverse voltage when on/off |
1500V max (EN60947-5-1) |
|
Pollution degree (environmental conditions) |
Pollution degree 3 (EN60947-5-1) |
|
Electric shock protection grade |
Class I (with ground terminal) |
|
Vibration |
Malfunction |
10 ~ 55Hz 0.75mm single amplitude |
Impact |
Duration |
1,000m/s2 |
Malfunction |
300m/s2 |
|
Ambient temperature |
Using:-20~+80℃(With no icing) |
|
Ambient humidity |
Less than 95% RH |
|
Weight |
About 250g |
Note 1. The above are initial values.
Note 2. Values of some models may be different from the above, please contact us for details.
*1. The protection structure is tested based on method predetermined by standard (EN69047-5-1), please confirm the sealing in advance according to the operating environment and
conditions.
*2. The conditions of life are the values under the ambient temperature of 5~35℃ and humidity of 40 to 70% RH. For other detailed conditions, please contact us.