C4N-4125
◼Forced open action device(NC contacts only), to disconnect the contact
◼when the contact has fusing and other failures
◼Strengthened top seal structure improves the sealing performance
◼Built-in contact holder has fast-action type: 1NC/1NO; Slow-action: 1NC
/1NO and 2NC
Item |
Code |
Description |
①Conduit / connector size |
1 |
Pg13.5 (1 conduit type) |
4 |
M20 (1 conduit type) |
|
5 |
Pg13.5 (2 conduits type) |
|
8 |
M20 (2 conduits type) |
|
②Built-in switch |
1 |
1NC/1NO (quick-action type) |
2 |
2NC (quick-action type) |
|
A |
1NC/1NO (slow-action type) |
|
B |
2NC (slow-action type) |
|
③Head and driving rod |
20 |
Roller lever (resin lever, resin ball) |
22 |
Roller lever (metal lever, resin ball) |
|
25 |
Roller lever (metal lever, metal resin ball) |
|
2G |
Adjustable roller lever, Form Lock (metal lever, resin ball) |
|
2H |
Adjustable roller lever, Form Lock (metal lever, rubber ball) |
|
2M |
Adjustable roller lever, Form Lock (metal lever, metal resin ball) |
|
31 |
Top plunger type |
|
32 |
Top plunger ball type |
|
62 |
Unilateral cantilever ball type (horizontal) |
|
72 |
Unilateral cantilever ball type (vertical) |
|
80 |
Whisker type |
|
87 |
Plastic stick type |
Protection level |
IP66 |
|
Life |
Electrical |
More than 500,000 times (AC250V 3A, resistive load) |
Operating speed |
1mm-0.5m/s(C4N-4120) |
|
Operating frequency |
Electrical: 30 operations/min |
|
Contact resistance |
25 mΩ or less |
|
Minimum working load |
1mA resistive load below DC5V (N standard reference value) |
|
Rated insulation voltage (Ui) |
300V |
|
Electric shock protection grade |
Class II (double insulated) |
|
Pollution degree (Using conditions) |
Pollution degree 3 (EN60947-5-1) |
|
Withstand voltage (EN60947-5-1) |
Between homopolar terminals: 2.5kV |
|
Between heteropolar terminals: 2.5kV |
||
Between terminals and uncharged metal parts: 6kV |
||
Insulation resistance |
Above 100MΩ |
|
Contact gap |
Minimum 2×0.5mm quick-action type,
Minimum 2×2mm slow-action type
|
|
Vibration |
Malfunction |
10 ~ 55Hz 0.75mm single amplitude |
Impact |
Duration |
1,000m/s2 |
Malfunction |
300m/s2 |
|
Ambient temperature |
Using:-20~+70℃(With no icing) |
|
Ambient humidity |
Less than 95% RH |
|
Weight |
About 82g (D4N-1120)
About 99g (D4N-5120)
|
Note 2. Once the contact is connected to a standard load, it can not be used to connect a smaller load. If so, the contact may result in rough surface, thus losing contact reliability.
*1. The protection level is gotten based on test method of (EN60947-5-1). Please make sure its sealing under actual environmental conditions before use. The switch box has dust and oil resistance structure, but it should be used in places without dust, oil and chemicals. Otherwise it may lead to premature wear, damage or malfunction.
2.The durability is for ambient temperature of 5℃ ~ 35℃ and humidity of 40% to 70% RH. For additional details, please contact us
*3. When the ambient temperature is above 35℃ , more than 2 circuits 3A 250VAC
loads are prohibited.
*4. The values will vary with different switching frequency, environmental conditions, reliability level and other factors. Please confirm on the actual load in advance.
Forced Disconnecting Mechansim
Quick-action type (1NC/1NO)(2NC), slow-action type (2NC)
Model
Action characteristics |
C4N-□120 C4N-□220 C4N-□B20 |
C4N-□122 C4N-□222 C4N-□B22 |
C4N-□125 C4N-□225 C4N-□B25 |
C4N-□226 C4N □B26 |
C4N-□131 C4N-□231 C4N-□B31 |
C4N-□132 C4N-□232 C4N-□B32 |
C4N-□162 C4N-□262 C4N-□B62 |
C4N-□172 C4N-□272 C4N-□B72 |
C4N-□12H C4N-□22H C4N-□B2H |
C4N- 12G C4N-□12M C4N-□22G C4N-□B2G*4 |
C4N-□□80 |
C4N- □□ 87 |
||
Action force |
OF |
Max. |
5.0N |
6.5N |
6.5N |
5.0N |
5.0N |
4.5N |
1.5N |
1.5N |
||||
Restore force |
RF |
Min. |
0.5N |
1.5N |
1.5N |
0.8N |
0.8N |
0.4N |
|
|
||||
Pretravel |
PT |
|
18~27° |
2mm |
2mm |
4mm |
4mm |
18 ~ 27° |
15° |
15° |
||||
Overtravel |
OT |
Min. |
40° |
4mm |
4mm |
5mm |
5mm |
40° |
|
|
||||
Poor response travel |
MD |
Max.*1 |
14° |
1mm |
1mm |
1.5mm |
1.5mm |
14° |
|
|
||||
Action position |
OP |
|
—— |
18.2±0.5mm |
28.6±0.8mm |
37±0.8mm |
27±0.8mm |
—— |
|
|
||||
Total travel |
TT |
*2 |
(80° ) |
(6mm) |
(6mm) |
(9mm) |
(9mm) |
(80° ) |
|
|
||||
Forced disconnected pretravel |
DOT |
Min.*3 |
50° |
3.2mm |
3.2mm |
5.8mm |
4.8mm |
50° |
|
|
||||
Forced disconnected force |
DOF |
Min.*3 |
20N |
20N |
20N |
20N |
20N |
20N |
|
*1. Only for quick-action type.
*2. Reference values.
*3. Only for slow-action type. For safe use, please make sure that all values are within the range of maximum or minimum.