TZ-8111
◼Double circuit type of limit switch
◼Conduit design for convenient cabling
◼Various actuators for different applications
◼Small size, water-proof and oil-proof construction
◼High mechanical strength,consists of intensive plastic and aluminum cast
◼Built-in contact box has double-spring and long mechanical life Smooth operation with larger over travel distance
-
Ratings
Rated Voltage
Noninductive Load (A)
Inductive Load (A)
Resistance Load
Lamp Load
Inductive Load
Motor Load
NC
NO
NC
NO
NC
NO
NC
NO
125VAC
250VAC
5
55
51.5
10.7
0.5
3
33
32
1.51
0.88VDC
5
5
3
3
5
4
3
3
14VDC
5
5
3
3
4
4
3
3
30VDC
5
5
3
3
4
4
3
3
125VDC
0.4
0.4
250VDC
0.2
0.2
Inrush Current
N.C: below 24A, N.O: below 12A
NOTES: 1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec. max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
3.Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.
-
Operation speed
5mm-0.5m/s
Operating frequency
Electical: 30 operations/min
Contact resistance
25mΩ max. (initial value)
Insulation resistance
100mΩ min. (below 500VDC)
Dielectric strength
1000VAC, 50/60 Hz for 1 minute between terminals of the same polarity
1500VAC, 50/60 Hz for 1 minute between current-carrying and non--current-carrying metal parts
1500VAC, 50/60 Hz for 1 minute between each terminal and ground
Vibration
10-55Hz,1.5mm double amplitude
Shock
Mechanical durable: 1, 000m/Sec2 (about 100G'S)
Malfunction: 300m/Sec2 (about 30G'S)
Ambient temperature
Using:-20~+70℃(With no icing)
Humidity
<95% RH
Electrical life
500,000 operations above
Degree of protection
IP65
Operating Characteristics
Model |
TZ-8 |
TZ-8104 TZ-8105 |
TZ-8108 TZ-8109 |
TZ-8107 |
TZ-8111 |
TZ-8112/8122 |
TZ-8166/8167/8168/8169 |
Operating force
|
OF(Max.) |
750g |
750g |
750g |
900g |
900g |
150g |
Release force
|
RF(Min.) |
100g |
100g |
100g |
150g |
150g |
- |
Pre-travel
|
PT(Max.) |
20° |
20° |
20° |
1.5mm |
1.5mm |
30mm |
Over travel
|
OT(Min.) |
50° |
50° |
50° |
4mm |
4mm |
- |
Movement differential |
MD(Max.) |
12° |
12° |
12° |
1mm |
1mm |
- |
Operating position
|
OP(mm.) |
- |
- |
- |
26±0.8mm |
37±0.8mm |
- |