CJF40X-20
◼Long sensing distance 50mm
◼Exclusively designed IC for improving anti-jamming capability
◼Inside surge protection, reverse polarity protection, overcurrent
protection
◼Red LED status indication, easy to confirm work situation
◼Protection structure IP65(IEC standard)
Item |
Code |
Description |
1 Company code |
C |
Company code |
2 Product name |
J |
Inductive proximity sensor |
3 Shape of shell |
F |
Square |
4 Dimension code |
40X |
Rectangle 40 |
5 Product type |
Without |
High-end type |
6 Detection distance |
20 |
20=20mm |
7 Output mode |
K |
AC 2wires |
L |
DC 2wires |
|
P |
PNP 3wires |
|
N |
NPN 3wires |
|
8 Output state |
A |
NO |
B |
NC |
|
C |
NO+NC |
|
9 Connection |
Without |
Without: Lead wire |
T |
Plug-in |
|
R |
Wiring leads Plug-in |
Model |
CJF40X-20LA CJF40X-20LB CJF40X-20NA CJF40X-20NB CJF40X-20PA CJF40X-20PB CJF40X-20KA CJF40X-20KB |
CJF40Y-20LA CJF40Y-20LB CJF40Y-20NA CJF40Y-20NB CJF40Y-20PA CJF40Y-20PB CJF40Y-20KA CJF40Y-20KB |
CJF80-50LA CJF80-50LB CJF80-50NA CJF80-50NB CJF80-50PA CJF80-50PB CJF80-50KA CJF80-50KB |
Sensing distance |
20mm |
20mm |
50mm |
Hysteresis |
Max. 10% of sensing distance |
||
Standard sensing target |
75×75×1mm |
75×75×1mm |
120×120×1mm |
Setting distance |
0~15.5mm |
0~15.5mm |
0~40mm |
Power supply (Operating voltage) |
10-30VDC / 24-250VAC |
||
Leakage current |
Max.10mA |
||
Response frequency (※1) |
DC 200Hz / AC 20Hz |
||
Residual voltage |
DC : 3.5V Max. 3.5V DC : 1V Max. 1.0V AC : 10V Max. 10V |
||
Affection by Temp. |
Max. ±10% for sensing distance at ambient temperature 20℃ |
||
Control output |
Max. 200mA |
||
Insulation resistance |
Min. 50MΩ(at 500VDC megger) |
||
Dielectric strength |
1500VAC 50/60Hz for 1minute |
||
Vibration |
1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
||
Shock |
500m/s2(approx. 50G) X, Y, Z directions for 3 times |
||
Indicator |
Operation indicator(red LED) |
||
Ambient temperature |
-25~+70℃ ( No icing) |
||
Storage temperature |
-30~+80℃ (No icing) |
||
Ambient humidity |
35~95%RH ( No condensation) |
||
Protection circuit |
Surge protection circuit, Reverse polarity protection circuit, Overcurrent protection circuit |
||
Material |
Case: PBT, Standard cable(Grey): Polyvinyl chloride(PVC) |
||
Protection |
IP65 |
(※1): The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.