CJY12E-04T
◼Orange mark for standard type
◼Light green mark for high-end type
◼Exclusively designed IC for improving anti-jamming capability
◼◼Inside surge protection, reverse polarity protection
◼◼Long use-life cycle and high reliability, easy install, enconomic price
◼◼Red LED status indication, easy to confirm work situation
◼◼Protection structure IP65(IEC standard)
◼◼Replaceable for limit switches
Item |
Code |
Description |
1 Company code |
C |
Company code |
2 Product name |
J |
Inductive proximity sensor |
3 Shape of shell |
Y |
Cylinder-shaped |
4 Dimension code |
18 |
18=M18 |
5 Product type |
Without |
Without = High-end type( Light green head) |
E |
E = Standard type(Orange head) |
|
6 Detection distance |
08 |
08=8mm |
7 Output mode |
K |
AC 2wires |
L |
DC 2wires |
|
P |
PNP 3wires |
|
N |
NPN 3wires |
|
8 Output state |
A |
NO |
B |
NC |
|
C |
NO+NC |
|
9 Connection |
Without |
Without: Lead wire |
T |
Plug-in |
|
R |
Wiring leads Plug-in |
Proper Usage
Mutual-interference
When several proximity sensors are mounted close to one another a malfunction of the sensor may be caused due to mutual interference.Therefore, be sure to provide a minimum distance between the two sensors as below chart indicates.
Inflfluence by surrounding metals
When sensors are mounted on metallic panel, you must prevent the sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart indicates.
DC 3-wire type
Model |
High-end type |
CJY12-02NAT CJY12-02NBT CJY12-02NCT CJY12-02PAT CJY12-02PBT CJY12-02PCR |
CJY12-04NAT CJY12-04NBT CJY12-04NCT CJY12-04PAT CJY12-04PBT CJY12-04PCR |
CJY18-05NAT CJY18-05NBT CJY18-05NCT CJY18-05PAT CJY18-05PBT CJY18-05PCR |
CJY18-08NAT CJY18-08NBT CJY18-08NCT CJY18-08PAT CJY18-08PBT CJY18-08PCR |
CJY30-10NAT CJY30-10NBT CJY30-10NCT CJY30-10PAT CJY30-10PBT CJY30-10PCR |
CJY30-15NAT CJY30-15NBT CJY30-15NCT CJY30-15PAT CJY30-15PBT CJY30-15PCT |
Standard type |
CJY12E-02NAT CJY12E-02NBT CJY12E-02NCT CJY12E-02PAT CJY12E-02PBT CJY12E-02PCT |
CJY12E-04NAT CJY12E-04NBT CJY12E-04NCT CJY12E-04PAT CJY12E-04PBT CJY12E-04PCT |
CJY18E-05NAT CJY18E-05NBT CJY18E-05NCT CJY18E-05PAT CJY18E-05PBT CJY18E-05PCT |
CJY18E-08NAR CJY18E-08NBR CJY18E-08NCT CJY18E-08PAT CJY18E-08PBT CJY18E-08PCT |
CJY30E-10NAR CJY30E-10NBR CJY30E-10NCT CJY30E-10PAT CJY30E-10PBT CJY30E-10PCT |
CJY30E-15NAR CJY30E-15NBR CJY30E-15NCT CJY30E-15PAT CJY30E-15PBT CJY30E-15PCT |
|
Sensing distance |
2mm |
4mm |
5mm |
8mm |
10mm |
15mm |
|
Hysteresis |
Max. 10% of sensing distance |
||||||
Standard sensing target |
12×12×1mm |
18×18×1mm |
25×25×1mm |
30×30×1mm |
45×45×1mm |
||
Setting distance |
0~1.4mm |
0~2.8mm |
0~3.5mm |
0~5.6mm |
0~7mm |
0~10.5mm |
|
Power supply (Operating voltage) |
12-24VDC (10-30VDC) |
||||||
Leakage current |
Max.10mA |
||||||
Response frequency (※1) |
1000Hz |
500Hz |
500Hz |
350Hz |
350Hz 400Hz |
200Hz |
|
Residual voltage |
Max. 1.0V |
||||||
Affection by Temp. |
Max. ±10% for sensing distance at ambient temperature 20℃ |
||||||
Control output |
Max. 200mA |
||||||
Insulation resistance |
Min. 50MΩ(at 500VDC megger) |
||||||
Dielectric strength |
1500VAC 50/60Hz for 1minute |
||||||
Vibration |
1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
||||||
Shock |
500m/s2(approx. 50G) X, Y, Z directions for 3 times |
||||||
Indicator |
Operation indicator(red LED) |
||||||
Ambient temperature |
-25~+70℃ ( No icing) |
||||||
Storage temperature |
-30~+80℃ ( No icing) |
||||||
Ambient humidity |
35~95%RH ( No condensation) |
||||||
Protection circuit |
Surge protection circuit, Reverse polarity protection circuit, Overcurrent protection circuit |
||||||
Material |
Case/Nut: Nickel plated Brass, Washer: Nickel plated lron, Sensing surface: PBT |
||||||
Protection |
IP65 |
(※1): The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
DC 2-wire type
Model |
High-end type |
CJY12-02LAT CJY12-02LBT |
CJY12-04LAT CJY12-04LBT |
CJY18-05LAT CJY18-05LBT |
CJY18-08LAT CJY18-08LBT |
CJY30-10LAT CJY30-10LBT |
CJY30-15LAT CJY30-15LBT |
Standard type |
CJY12E-02LAT |
CJY12E-04LAT |
CJY18E-05LAT |
CJY18E-08LAT |
CJY30E-10LAT |
CJY30E -15LAT |
|
Sensing distance |
2mm |
4mm |
5mm |
8mm |
10mm |
15mm |
|
Hysteresis |
Max. 10% of sensing distance |
||||||
Standard sensing target |
12×12×1mm |
18×18×1mm |
25×25×1mm |
30×30×1mm |
45×45×1mm |
||
Setting distance |
0~1.4mm |
0~2.8mm |
0~3.5mm |
0~5.6mm |
0~7mm |
0~10.5mm |
|
Power supply |
12-24VDC (10-30VDC) |
||||||
Leakage current |
Max.0.6mA |
||||||
Response frequency (※1) |
1000Hz |
500Hz |
500Hz |
350Hz |
350Hz |
200Hz |
|
Residual voltage |
Max. 3.5V |
||||||
Affection by Temp. |
Max. ±10% for sensing distance at ambient temperature 20℃ |
||||||
Control output |
Max. 200mA |
||||||
Insulation resistance |
Min. 50MΩ(at 500VDC megger) |
||||||
Dielectric strength |
1500VAC 50/60Hz for 1minute |
||||||
Vibration |
1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
||||||
Shock |
500m/s2(approx. 50G) X, Y, Z directions for 3 times |
||||||
Indicator |
Operation indicator(red LED) |
||||||
Ambient temperature |
-25~+70℃ ( No icing) |
||||||
Storage temperature |
-30~+80℃ ( No icing) |
||||||
Ambient humidity |
35~95%RH ( No condensation) |
||||||
Protection circuit |
Surge protection circuit |
||||||
Material |
Case/Nut: Nickel plated Brass, Washer: Nickel plated Iron, Sensing surface: PBT |
||||||
Protection |
IP65 |
(※1): The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
AC 2-wire type
Model |
High-end type |
/ |
CJY12-04KAT CJY12-04KBT |
CJY18-05KAT CJY18-05KBT |
CJY18-08KAT CJY18-08KBT |
CJY30-10KAT CJY30-10KBT |
CJY30-15KAT CJY30-15KBT |
Standard type |
CJY12E-02KAT CJY12E-02KBT |
CJY12E-04KAT CJY12E-04KBT |
CJY18E-05KAT CJY18E-05KBT |
CJY18E-08KAT CJY18E-08KBT |
CJY30E-10KAT CJY30E-10KBT |
CJY30E-15KAT CJY30E-15KBT |
|
Sensing distance |
2mm |
4mm |
5mm |
8mm |
10mm |
15mm |
|
Hysteresis |
Max. 10% of sensing distance |
||||||
Standard sensing target |
12×12×1mm |
18×18×1mm |
25×25×1mm |
30×30×1mm |
45×45×1mm |
||
Setting distance |
0~1.4mm |
0~2.8mm |
0~3.5mm |
0~5.6mm |
0~7mm |
0~10.5mm |
|
Power supply (Operating voltage) |
90-250VAC |
||||||
Leakage current |
Max.10mA |
||||||
Response frequency (※1) |
20Hz |
||||||
Residual voltage |
Max. 10V |
||||||
Affection by Temp. |
Max. ±10% for sensing distance at ambient temperature 20℃ |
||||||
Control output |
Max. 200mA |
||||||
Insulation resistance |
Min. 50MΩ(at 500VDC megger) |
||||||
Dielectric strength |
1500VAC 50/60Hz for 1minute |
||||||
Vibration |
1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
||||||
Shock |
500m/s2(approx. 50G) X, Y, Z directions for 3 times |
||||||
Indicator |
Operation indicator(red LED) |
||||||
Ambient temperature |
-25~+70℃ (No icing) |
||||||
Storage temperature |
-30~+80℃ ( No icing) |
||||||
Ambient humidity |
35~95%RH ( No condensation) |
||||||
Protection circuit |
Surge protection current |
||||||
Material |
Case/Nut: Nickel plated Brass, Washer: Nickel plated Iron, Sensing surface: PBT |
||||||
Protection |
IP65 |
(※1): The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance
utual-interference When several proximity sensors are mounted close to one another a malfunction of the sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors as below chart indicates. |
Influence by surrounding metals When sensors are mounted on metallic panel, you must prevent the sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart indicates. |
Model |
CJY12-02R |
CJY12-04R |
CJY18-05R |
CJY18-08R |
CJY30-10R |
CJY30-15R |
CJY12E-02R |
CJY12E-04R |
CJY18E-05R |
CJY18E-08R |
CJY30E-10R |
CJY30E-15R |
|
A |
12 |
24 |
30 |
48 |
60 |
90 |
B |
24 |
36 |
36 |
54 |
60 |
90 |
0 |
11 |
0 |
14 |
0 |
15 |
|
φd |
12 |
36 |
18 |
54 |
30 |
90 |
m |
6 |
12 |
15 |
24 |
30 |
45 |
n |
18 |
36 |
27 |
54 |
45 |
90 |