CJY30S-17R
◼Long sensing distance (1.5 to 2 times longer sensing distance
guaranteed compared to existing models)
◼Exclusively designed IC for improving anti-jamming capability
◼Inside surge protection, reverse polarity protection, overcurrent protection
◼Long use-life cycle and high reliability, easy install, enconomic price
◼Red LED status indication, easy to confirm work situation
◼Protection structure IP67(IEC standard)
◼Replaceable for limit switches
Item |
Code |
Description |
1 Company code |
C |
Company code |
2 Product name |
J |
Inductive proximity sensor |
3 Shape of shell |
Y |
Cylinder-shaped |
4 Dimension code |
18 |
18=M18 |
5 Product type |
S |
Long-range type |
6 Detection distance |
15 |
15=15mm |
7 Output mode |
K |
AC 2wires |
L |
DC 2wires |
|
P |
PNP 3wires |
|
N |
NPN 3wires |
|
8 Output state |
A |
NO |
B |
NC |
|
C |
NO+NC |
|
9 Connection |
Without |
Without: Lead wire |
T |
Plug-in |
|
R |
Wiring leads Plug-in |
DC 3-wire type
Model |
CJY12S-04NAR CJY12S-04NBR CJY12S-04NCR CJY12S-04PAR CJY12S-04PBR CJY12S-04PCR |
CJY12S-07NAR CJY12S-07NBR CJY12S-07NCR CJY12S-07PAR CJY12S-07PBR CJY12S-07PCR |
CJY18S-10NAR CJY18S-10NBR CJY18S-10NCR CJY18S-10PAR CJY18S-10PBR CJY18S-10PCR |
CJY18S-15NAR CJY18S-15NBR CJY18S-15NCR CJY18S-15PAR CJY18S-15PBR CJY18S-15PCR |
CJY30S-17NAR CJY30S-17NBR CJY30S-17NCR CJY30S-17PAR CJY30S-17PBR CJY30S-17PCR |
CJY30S-25NAR CJY30S-25NBR CJY30S-25NCR CJY30S-25PAR CJY30S-25PBR CJY30S-25PCR |
Sensing distance |
4mm |
7mm |
10mm |
15mm |
17mm |
25mm |
Hysteresis |
Max. 10% of sensing distance |
|||||
Standard sensing target |
12×12×1mm |
25×25×1mm |
20×20×1mm |
40×40×1mm |
45×45×1mm |
75×75×1mm |
Setting distance |
0~2.8mm |
0~5.6mm |
0~4.9mm |
0~9.8mm |
0~10.5mm |
0~17.5mm |
Power supply |
12-24VDC (10-30VDC) |
|||||
Leakage current |
Max.10mA |
|||||
Response frequency (※1) |
400Hz |
300Hz |
300Hz |
200Hz |
100Hz |
100Hz |
Residual voltage |
Max. 1V |
|||||
Affection by Temp. |
Max. ±10% for sensing distance at ambient temperature 20℃ |
|||||
Control output |
Max. 200mA |
|||||
Insulation resistance |
Min. 50MΩ(at 500VDC megger) |
|||||
Dielectric strength |
1500VAC 50/60Hz for 1minute |
|||||
Vibration |
1mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours |
|||||
Shock |
500m/s2(approx. 50G) X, Y, Z directions for 3 times |
|||||
Indicator |
Operation indicator(red LED) |
|||||
Ambient temperature |
-25~+70℃ ( No icing) |
|||||
Storage temperature |
-30~+80℃ ( No icing) |
|||||
Ambient humidity |
35~95%RH ( No condensation) |
|||||
Protection circuit |
Surge protection circuit, Reverse polarity protection circuit, Overcurrent protection circuit |
|||||
Material |
Case/Nut: Nickel plated Brass, Washer: Nickel plated Iron, Sensing surface: PBT |
|||||
Cable |
connector |
φ4.8, 3P,4P 300mm, M12 connector |
||||
Protection |
IP67 |
(※1) The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
Mutual-interference When several proximity sensors are mounted close to one another a malfunction of the sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors as below chart indicates. |
Influence by surrounding metals When sensors are mounted on metallic panel, you must prevent the sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart indicates. |
Model |
CJY12S-04R |
CJY12S-07R |
CJY18S-10R |
CJY18S-15R |
CJY30S-17R |
CJY30S-25R |
A |
24 |
48 |
42 |
84 |
90 |
150 |
B |
24 |
36 |
36 |
54 |
60 |
90 |
e |
0 |
11 |
0 |
14 |
0 |
15 |
φd |
12 |
36 |
18 |
54 |
30 |
90 |
m |
12 |
24 |
21 |
42 |
45 |
75 |
n |
18 |
36 |
27 |
54 |
45 |
90 |