Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

Double circuit type of limit switch

High mechanical strength, consists of intensive plastic and

aluminum cast

Water-proof and oil proof construction

Built-in contact box has double-spring and long mechanical life

Smooth operation with larger over travel distance

Various actuators for different application

Ratings

Rated Voltage

Noninductive Load (A)

Inductive Load (A)

Resistance Load

Lamp Load

Inductive Load

Motor Load

NC

NO

NC

NO

NC

NO

NC

NO

125VAC

250VAC

5
5

5
5

1.5
1

0.7

0.5

3
3

3
3

2
1.5

1
0.8

8VDC

5

5

3

3

5

4

3

3

14VDC

5

5

3

3

4

4

3

3

30VDC

5

5

3

3

4

4

3

3

125VDC

0.4

0.4

250VDC

0.2

0.2

Inrush Current

N.C: below 24A, N.O: below 12A

NOTES:1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
3.Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.

Operation speed

5mm-0.5m/s

Operating frequency

Electical: 30 operations/min

Contact resistance

25mΩ max. (initial value)

Insulation resistance

100mΩ min. (below 500VDC)

Dielectric strength

1000VAC, 50/60 Hz for 1 minute between terminals of the same polarity

1500VAC, 50/60 Hz for 1 minute between current-carrying and non--current-carrying metal parts

1500VAC, 50/60 Hz for 1 minute between each terminal and ground

Vibration

10-55Hz,1.5mm double amplitude

Shock

Mechanical durable: 1, 000m/Sec2 (about 100G'S)

Malfunction: 300m/Sec2 (about 30G'S)

Ambient temperature

Using:-20~+70℃(With no icing)

Humidity

<95% RH

Electrical life

500,000 operations above

Degree of protection

IP65

NOTES:The default size of conduit connector is M18x1.5.Conduit connector size is PG11.5, with product model number plus (-P), example:CSA-012-P.

Operating Characteristics

Model

CSA

CSA-001

CSA-003

CSA-012

CSA-021

CSA-021M

CSA-041

CSA-031

CSA-031M

CSA-051

CSA-061

CSA-071

CSA-081

Operating force

OF

(Max.)

800g

800g

800g

400g

400g

400g

400g

150g

150g

150g

Release force

RF

(Min.)

400g

400g

400g

100g

100g

100g

100g

50g

50g

50g

Pre-travel

PT

(Max.)

1.8mm

1.8mm

1.8mm

20°

20°

20°

20°

30mm

30mm

30mm

Tripping position

TP

±10%

2.0mm

2.0mm

2.0mm

22.5°

22.5°

22.5°

22.5°

22.5°

22.5°

22.5°

Movement differential

MD

(Max.)

1.2mm

1.2mm

1.2mm

10°

10°

10°

10°

14°

14°

14°

Over travel

OT

(Min.)

4.0mm

4.0mm

4.0mm

75°

75°

75°

75°

20mm

20mm

20mm

Total travel

TT

(Min.)

5.8mm

5.8mm

5.8mm

95°

95°

95°

95°

50mm

50mm

50mm

Rotary indexing

 

 

 

 

22.5°

22.5°

22.5°

22.5°

 

 

      

A powerful company

  •  NO. 258. Wei Eleven Road, Yueqing Economic Development                   Zone, Yueqing City, Zhejiang Province,P.R. China
  •  +86 18857728107

CONTACT US

Copyright © 2020 Singoo