Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

Current:0.5A~400A

Voltage:12V~680V

General Install Size

Vacuum Weld Techinics

Led indicator showing “ON” or “OFF”

Protect Panel

IEC standard

Input & output type could chose DC/AC AC/AC DC/DC

Overview

Solid State Relay(CSR) is industrial control appliances which use power semiconductor devices for main control part,compare with traditional magnetic contact industrial controllers, it is more high-powered, intelligent, digital, systematic and green development.

according switch mode CSR have zero-cross and random type. When the input control signal, random type conduction immediately, zero cross type need load voltage turn to zero region just can conduction. Revocation of the control signal,all can cut off when less than maintenance current. zero cross type may cause the maximum half-cycle delay, but reduces the impact of the load and radiofrequency interference, is the ideal switching devices.Random type fast response,suitable for dimmer,thermostats resistive loads and some inductive load applications.

When the CSR turn off, if in the phase current and voltage have different, will have a large rise rate (dv/dt) on the triac, such as dv/dt higher than Triac standatrd (300V/us), will result in delay shutdown even failure. use anti-parallel thyristor's CSR(powerful type) will been greatly improved at dv/dt(dv / dt is 500V/us). Therefore, in the field of capacitive load or inductive load, suggest the use powerful type CSR. CNTD's CSR are all powerful type.

Solid-state voltage regulator consists of thyristor switching circuit, resistance-capacitance phase shifting circuit,lag circuit and over-voltage absorption circuit.The use of only one external potentiometer can be used to achieve AC power regulation.In many occasions can replace the heavy contact voltage lighting power supply,voltage,temperature,brightness, speed and other analog adjustment.

1.CSR=CNTD Single Phase Solid State Relay

CTR=CNTD Three Phase Solid State Relay

2.None= Improve Design Type(Light Green)

E=Standard Economic Type(Gray)

3.Rated Operation Current

4.Comtrol & Load voltgge type

DA=DC(4-32V)AC(24-380V) AA=AC(80-250V)AC(24-380V)

DD=DC(4-32V)DC(12-240V) VA=Voltage regulator24 380VAC)

5.None=Zero Cross Trigger

R=Radom Switch

Applications

AC DC switch & Temp control

Automate Control

CNC machinery

Packaging machinery

Textile machinery

Glass machinery

Plastic machinery

APPLICATIONS

Specification

input parameter

output parameter

Safe Load

Control Voltage

Control Current

Start Current

Close Voltage

Operating Current

Operating Voltage

Insulate voltage

Protection

Resistive Load

Inductive Load

Over Voltage

Over Current

CSR

DC/ AC

4-32
V DC

<20mA

≥5mA

≤1.5V
DC

10-100A

24-480
V AC

≥2500
VAC

RC MOV

Fast Fuse

60%

40%

AC/AC

80-250
V AC

<30mA

≥5mA

≤10V
AC

10-100A

24-480
V AC

Industry class

4-32
V DC

<20mA

≥5mA

≤1.5V
DC

100-800A

24-480
V AC

DC/DC

3-32
V DC

<25mA

≥5mA

≤1.5V
DC

10-40A

12-250
V DC

Diode

CTR

4-32
V DC

<30mA

≥9ma

≤2.5V
DC

10-120A

24-480
V AC

RC MOV

Fast Fuse

Solid StateVoltage Regulator

Potentiometer 500KΩ/1/4W

10-40A

10-250V AC

RC MOV

Fast Fuse

Notes:

1.Strictly prohibit for load short circuit.Can use fast fuse.

2.Ling time working current can't over 70% of the nominal value.

3.Heatsink temperature can't over 75℃.

4.Use at inductive load area, adding varistor for protect is better.

SPECIFIFICATIONS

Model

CSR-DA

CSR-AA

CSR-VA

CSR-DD

CTR-DA

CSRE-DA

CSRE-AA

CSRE-VA

CSRE-DD

CTRE-DA

Operation Current

10A,25A,40A

60A,80A,100A

10A,25A,40A

60A,80A,100A

10A,25A,40A

10A,25A,40A

10A,25A,40A

60A,80A,
100A,120A

Operation Voltage

24-480V AC

24-480V AC

10-250V AC

12-250V DC

24-480V AC

Control Voltage

4-32V DC

80-250V AC

500KΩ/1/4W

3-32V DC

4-32V DC

Control Current

DC 3-25mA

AC≤12mA

/

DC 3-25mA

DC 3-25mA

V TM

≤1.5V

≤1.5V

≤1.5V

≤1.5V

≤1.5V

≤2.3V

≤1.5V

≤1.5V

I RRM

≤10mA

≤20mA

≤10mA

≤20mA

≤5mA

≤5mA

≤15mA

≤15mA

T Q

≤10mS

≤10mS

≤10mS

≤10mS

≤10mS

V iso

2500V AC

2500V AC

2500V AC

2500V AC

2500V AC

R iso

1000mΩ 500V DC

1000mΩ 500V DC

1000mΩ 500V DC

1000mΩ 500V DC

1000mΩ 500V DC

Tj

-30~+80℃

-30~+80℃

-30~+80℃

-30~+80℃

-30~+80℃

Weight

90g

140g

90g

140g

90g

90g

350g

450g