CTN4M

◼High-speed sampling
◼AI artificial intelligence adjustment algorithm
◼Dual PID heating and cooling intelligent adjustment
◼AT automatic calculation function
◼16-bit MCU high-speed operation accuracy
◼Dual digital display (PV / SV)
◼High-speed sampling rate of 100ms and display accuracy of 0.5%
◼SSR Drive output / Relay output / Current output optional
◼Terminal type wiring method conducive to wiring and
maintenance
Item |
Code |
Description |
① Name of the company |
C |
CNTD |
② Series |
TE |
Economical digital dual display PID temperature controller |
TN |
Standard digital dual display PID temperature controller |
|
TZ |
High precision digital dual display PID temperature controller |
|
③ Digit |
4 |
9999(4 Digit) |
④ Dimensions |
S |
48×48 |
V |
48×96 |
|
M |
72×72 |
|
L |
96×96 |
|
H |
96×48 |
|
⑤ Voltage supply |
2 |
24VAC 50/60Hz,24-48VDC |
4 |
Switch power supply(100-240V AC, 50HZ ) |
|
A-Z |
Custom power supply voltage |
|
⑥ Control output |
1 |
Relay |
2 |
Output |
|
3 □ |
Analog output: A: 0~20mA, 4-20mA, B: 0-5V, 1-5V |
|
4 |
Thyristor zero-crossing output |
|
5 |
Silicon controlled rectifier (5A) |
|
6 |
Relay output |
|
A-Z |
A-Z letter combination represents other or custom control output modes |
Item |
Code |
Description |
⑦ Alarm output |
1 |
Way relay |
2 |
Way relay |
|
3 |
1-way SSR |
|
4 |
1-way SSR |
|
A-Z |
A-Z letter combination represents other or custom control output modes |
|
⑧ Graduation |
None |
Thermocouple input K, E, J, L, T, R, S Thermal resistance input PT100, Cu50 (full function) |
A-Z |
A-Z letter combination, representing other or customized alarm output |
|
⑨ Transmission output |
None |
No such function |
T |
With transmission output function |
|
⑩ Graduation |
None |
No such function |
R |
With RS485 communication function |
Note 1: Analog output and transmission output cannot be selected at the
same time;
Note 2: Due to the limited number of 48 * 48 ports, the model selection
cannot be fully met. Please contact the manufacturer if necessary;
Note 3: For 48x48 size, if 485 communication is required in the control
output option, only 1/2/3 can be selected, not choose 6.
Rated voltage |
100-240V AC,50HZ |
Power consumption |
≤ 5VA |
Rated voltage |
Installation type II, Pollution degree 2 |
Storage Temperature |
-25℃ -65℃ (Avoid freezing) |
Esolution power |
1℃ , 0.1℃ (Adjustable) |
Wiring method |
Connecting terminal |
Measuring accuracy |
±0. 5%FS |
Memory Protection |
Non-volatile memory |
Installation conditions |
Installation type II, Pollution degree 2 |
Relay output |
Relay contact: AC220V/DC30V,3A |
Logic level output |
On: DC24V; Off: dc0 Below 5V; Maximum current: 30mA, load resistance ≥ 1K |
Overall dimension
Model |
|
Shell size (length, width and height) |
Hole size |
CTN4S |
48x48 |
48x48x71 |
45x45 |
CTN4V |
48x96 |
48x96x71 |
46x92 |
CTN4H |
96x48 |
96x48x71 |
91x45 |
CTN4M |
72x72 |
72x72x71 |
68x68 |
CTN4L |
96x96 |
96x96x71 |
92x92 |
High speed sampling
100ms high-speed sampling rate enables precise temperature control in applications requiring fast response speed.
SSR drive output method
Users can choose SSR and RELAY drive output. On this basis, ON/OFF control and manual output are added to achieve ideal temperature control.