CDT6-K

◼4 delay modes can be set.
◼Through the digital dial code setting, the setting is more
accurate.
◼Ultra-wide delay range, 0.1 seconds-99 hours can be set.
◼With AC/DC12V-240V ultra-wide operating voltage specifications
are optional.
◼The working status of the relay is indicated by the LED indicator.
◼Ultra-small size, only 18mm width, 35mm card rail installation.
Application
◼The multi-function time relay with digital setting can be used
for industrial equipment, lighting control, heating element
control, motor, and fan control. It has 4 delay modes and the
delay range covers 0.1 seconds to 99 hours.
|
No |
Item |
Code |
Description |
|
① |
Product name |
CDT6 |
Clamp rail type time relay |
|
② |
Function code |
K |
Dual function time relay (power delay,delay off) |
|
③ |
Output the number of contact groups |
1 |
Group 1 conversion |
|
2 |
Group 2 conversion |
||
|
④ |
Output contac |
08 |
Output contact 8A |
|
16 |
Output contact 16A |
||
|
⑤ |
Rated operating voltage |
W |
AC/DC12V-240V |
|
A-Z letter combination |
Custom voltage |
|
CDT6-K1 |
CDT6-K2 |
||
|
Function |
A,B,E,F |
||
|
Power terminal |
A1-A2 |
||
|
Rated control power supply voltage |
W (AC/DC12V-240V) |
AC/DC 12-240V(50-60Hz) |
|
|
Power consumption |
AC 0.09-3VA/DC 0.05-1.7W |
||
|
Alowable fluctuation range of power supply |
-15%;+10% |
||
|
Power indicator |
Green LED |
||
|
Delay range |
0.1 seconds-99 hours,normally open,normally closed |
||
|
Setting method |
Digital dial code setting |
||
|
Setting accuracy |
1% |
||
|
Repeatability |
0.2% |
||
|
Temperature fluctuation error |
0.05%/°℃,at=20℃ |
||
|
Output contact parameters |
Number of contacts |
1 set of conversion contacts |
2 sets of conversion contacts |
|
8A |
1*8A 250VAC/24VDC |
2*8A 250VAC/24VDC |
|
|
16A |
1*16A 250VAC/24VDC |
2*16A 250VAC/24VDC |
|
|
Minimum switching powe |
500mW |
||
|
Output relay indication |
Red LED |
||
|
Mechanical life |
1×10' |
||
|
Electrical life (resistive load) |
1×10⁵ |
||
|
Reset time |
Maximum 200ms |
||
|
Operating ambient temperature |
20℃ ~+55℃ |
||
|
Storage and transportation ambient temperature |
-35°℃ ~+75℃ |
||
|
nstallation method |
55 mm card rail installation |
||
|
Protection level |
P20 |
||
|
nstallation location |
Arbitrary |
||
|
nstallation altitude |
≤2000m |
||
|
Pollution level |
2 |
||
|
Wiring ability |
1×2.5mm²or 2×1.5mm²0.4N-m |
||
|
Dimensions |
90mm×18mm×65mm |
||
|
Weight |
67g |
80g |
|
Function diagramw

Wiring diagram

Shape and size (mm)

Delay setting

Panel diagram

Português