description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
FEATURES

Separate delay time and pulse width settings, different delay

times can be set.

Ultra-wide delay range, 0.1 seconds-100 days can be set (10 gears).

The delay time can be reset by shorting S-A1.

It has AC/DC 12V-240V ultra-wide operating voltage specifications

to choose from.

The working status of the relay is indicated by an LED indicator.

Ultra-small size, only 18mm width, 35mm card rail installation.

Application

It is used to delay and generate a pulse, which is used to delay

a certain load for a period of time.

No

ltem

Code

Description

Product name

CDT6

Clamp rail type time relay

Function code

P

Time delay pulse type time relay (delay pulse)

 

 

Output the number of contact groups

1

Group 1 conversion

2

Group 2 conversion

 

 

Output contact

10

Output contact 10A

16

Output contact 16A

 

 

 

 

Rated operating voltage

M

AC220V

w

AC/DC12V-240V

A-Z letter combination

Custom voltage

SPECIFIFICATIONS

CDT6-P1

CDT6-P2

Function

Delay pulse output

Power terminal

A1-A2

Rated control power supply voltage

 

w

(AC/DC12V-240V)

AC/DC 12-240V(50-60Hz)

Power consumption

AC 0.09-3VA/DC 0.05-1.7W

Rated control power supply voltage

 

M(AC220V)

AC 220V(50-60Hz)

Power consumption

AC max.6VA/1.3W

AC max.6VA/1.9W

Allowable fluctuation range of powe supply

-15%;+10%

Power indicator

Green LED

Delay range

0.1 seconds -100 days

Setting method

knob

Setting accuracy

10%

Repeatability

0.2%

Temperature fluctuation error

0.05%/℃.at=20℃(0.05%F,at=68F)

 

Output contact oarameters

Number of contacts

1 set of conversion contacts

2 sets of conversion contacts

10A

1*10A 250VAC/24VDC

2*10A 250VAC/24VDC

16A

1*16A 250VAC/24VDC

2*16A 250VAC/24VDC

Minimum switching power

500mW

Output relay indication

Red LED

Mechanical life

1×10⁷

Electrical life (resistive load)

1×10⁵

Reset time

Maximum 200ms

Operating ambient temperature

-20℃ ~+55℃

Storage and transportation ambient temperature

-35℃ ~+75℃

nstallation method

35 mm card rail installation

Protection level

IP20

Installation location

Arbitrary

nstallation altitude

≤2000m

Pollution level

2

Wring ability

1×2.5mm²or   2×1.5mm²0.4N·m

Dimensions

90mm×18mm×65mm

Weight

67g

80g

CONTROL OUTPUT DIAGRAM

Function diagramw

Wiring diagram

Shape and size (mm)

A powerful company

  •  NO. 258. Wei Eleven Road, Yueqing Economic Development                   Zone, Yueqing City, Zhejiang Province,P.R. China
  •  +86 18857728107

CONTACT US

Copyright © 2020 Singoo